Pressol mobiMASTER 450 l, Mobile Diesel Tank 24 V, 35 l/min, without Meter
€1,317.00*
Exact shipping costs are calculated at checkout · All shipping costs
- Mobile Diesel Tank
- 450 Liter Capacity
- Various Pumps Available
Delivery time: 5-10 Tage
Pressol mobiMASTER 450 l – Mobile Diesel Tank with Electric Pump 12 V, 24 V or 230 V, 35 to 65 l/min
The Pressol mobiMASTER 450 l is a mobile LLDPE diesel tank in Euro pallet size that may be moved filled by forklift or crane. The FMT vane pump delivers 35 l/min (12 V/24 V DC) or 65 l/min (230 V) – depending on the version with digital in-line meter.
Product features
- Transportable filled by forklift and crane, UN/ADR approval
- Pump compartment with lockable cover and gas spring
- Compact design in Euro pallet size
Technical data
- Manufacturer: PRESSOL Schmiergeräte GmbH (Germany)
- Fluids: diesel, heating oil, HVO 100
- Capacity: 450 l
- Material: LLDPE (polyethylene)
- Flow rate: 35 l/min (12/24 V), 65 l/min (230 V)
- Dimensions: 1200 x 800 x 912 mm (Euro pallet size)
- UN approval: un 31H2/Z/** **/CZ/IMET 20140/0/520
Available versions
| Item no. | Voltage | Flow rate | Meter | Nozzle |
|---|---|---|---|---|
| P-26420 | 12 V | 35 l/min | without | ZVABD |
| P-26421 | 24 V | 35 l/min | without | ZVABD |
| P-26430 | 12 V | 35 l/min | digital | ZVABD |
| P-26431 | 24 V | 35 l/min | digital | ZVABD |
| P-264234 | 230 V | 65 l/min | digital | ZVABD |
| P-26404 | 230 V | 65 l/min | without | ZVAD |
Applications
- Mobile diesel supply in agriculture, construction, forestry and landscaping
- Refuelling machines, generators and vehicles directly on site
Notes
Storing petrol in the tank is not permitted. Leak test every 2½ years and internal inspection every 5 years required. Manufacturer's warranty 5 years on tank and vane pump (excluding wear parts), 2 years on fitted components. Technical data subject to change by the manufacturer.
Häufige Fragen zu diesem Produkt
For which areas of application is the MobiMaster 450 liter suitable and when is it worthwhile compared to the mobiFitt 300 liter?
The MobiMaster 450 liter is the right choice if the daily consumption on the construction site is over 200 liters or if 4–6 machines have to be refueled every day. Compared to the mobiFitt 300L, it offers 50 % more range with similar transport effort – a one-time effort for placing it on the vehicle, and one tank filling supplies more machines without refilling in between. For smaller construction sites or individual machines we recommend the mobiFitt 125L or 200L.
Is the MobiMaster 450 liter ADR-approved and what changes compared to smaller tanks?
Yes – the MobiMaster 450 liter is ADR-approved (European Agreement concerning the International Carriage of Dangerous Goods by Road). Important: with 450 liters of diesel (UN 1202, Class 3), it is exactly at the ADR exemption limit for limited quantities. When fully filled, we recommend complying with the basic ADR requirements: orange warning plate, 2-kg ABC fire extinguisher, written instructions. For regular or commercial transport of this volume we recommend individual ADR consultation. As a WHG-certified specialist company under Section 62 AwSV (German Ordinance on Facilities Handling Substances Hazardous to Water), we will be happy to help.
Which vehicles are suitable for transporting the MobiMaster 450 liter and how heavy is it when filled?
When filled, the MobiMaster 450 liter weighs approx. 480 kg (450L diesel ≈ 378 kg + dead weight approx. 100 kg). It is therefore designed for heavy flatbed vehicles (payload min. 700 kg), trailers and low-loaders – light vans are generally not suitable. A forklift or hall crane is required for placing it on and removing it from the vehicle. The lashing points for tie-down straps according to EN 12195 are integrated in the frame.
Does the MobiMaster 450 liter have a 12V or 24V option?
The MobiMaster 450 liter (P-26420) is available in the 12V version. For operators with trucks or heavy construction machinery with a 24-volt on-board system, we recommend using a 24V-to-12V voltage converter or using a separate 12V battery as the power source for the pump. Alternatively, our range includes mobile tank systems with 24V pumps in other volume sizes – please contact us regarding your specific requirements.
What is the difference between MobiMaster and mobiFitt – are they different products?
Yes – MobiMaster and mobiFitt are two different product lines from Pressol that differ in design, volume and target group. The mobiFitt is available in the smaller volume sizes 125L, 200L and 300L and is designed for universal use on flatbed vehicles and trailers. The MobiMaster 450L is the largest model of this product family and is aimed at large construction sites and businesses with high daily consumption. Both lines are manufactured by Pressol, ADR-approved and suitable for diesel.
Pressol Schmiergeräte GmbH
Tiergartenstraße 5
79423 Heitersheim, Deutschland
Product safety information
Allgemeine Warn- und Sicherheitshinweise gemäß Produktsicherheitsgesetz (ProdSG) für mobile Dieseltankanlagen aus Kunststoff
1. Allgemeine Sicherheitshinweise:
- Verwendungszweck: Die Tankanlage ist ausschließlich für die Lagerung und den Transport von Diesel bestimmt. Verwenden Sie sie nicht für andere Flüssigkeiten wie Benzin, Chemikalien oder brennbare Flüssigkeiten.
- Sicherheitsstandards: Stellen Sie sicher, dass die Tankanlage den geltenden Sicherheitsstandards und -vorschriften entspricht, insbesondere für Gefahrguttransport.
2. Elektrische Sicherheit (bei Anlagen mit elektrischen Pumpen):
- Geeignete Stromquelle: Schließen Sie die Pumpe nur an die vorgeschriebene Stromquelle (z. B. 12V oder 230V) an.
- Kabel und Anschlüsse: Überprüfen Sie regelmäßig die elektrischen Kabel und Anschlüsse auf Abnutzung oder Beschädigungen. Ersetzen Sie beschädigte Teile sofort.
- Schutz vor Feuchtigkeit: Schützen Sie elektrische Komponenten vor Regen, Spritzwasser und Feuchtigkeit.
3. Umgang mit Diesel:
- Belüftung sicherstellen: Verwenden Sie die Tankanlage nur in gut belüfteten Bereichen, um die Ansammlung von gefährlichen Dämpfen zu vermeiden.
- Vermeidung von Zündquellen: Halten Sie die Tankanlage fern von offenen Flammen, Funken oder heißen Oberflächen.
- Persönliche Schutzausrüstung (PSA): Tragen Sie beim Umgang mit Diesel geeignete Handschuhe und Schutzbrille, um Hautkontakt und Augenkontamination zu vermeiden.
4. Befüllung und Entleerung:
- Sichere Befüllung: Verwenden Sie das integrierte Füllsystem gemäß den Herstelleranweisungen, um Überfüllungen oder Leckagen zu vermeiden.
- Automatik-Zapfventil: Nutzen Sie das Automatik-Zapfventil korrekt, um unkontrolliertes Austreten von Diesel zu verhindern.
- Regelmäßige Kontrolle: Prüfen Sie die Dichtungen und Anschlüsse vor jedem Einsatz auf Dichtheit.
5. Transport:
- Transportsicherung: Sichern Sie die Tankanlage während des Transports gemäß den geltenden Vorschriften, insbesondere bei Gefahrguttransport.
- Stabile Befestigung: Stellen Sie sicher, dass die Tankanlage auf einer ebenen und stabilen Fläche transportiert wird, um Umkippen oder Verrutschen zu vermeiden.
6. Wartung und Inspektion:
- Regelmäßige Wartung: Lassen Sie die Anlage regelmäßig von einem Fachmann warten, um Schäden oder Verschleiß frühzeitig zu erkennen.
- Reinigung: Reinigen Sie die Tankanlage nach den Herstellerangaben, um Dieselrückstände zu entfernen und Korrosion zu verhindern.
- Dichtheitsprüfung: Führen Sie regelmäßige Dichtheitsprüfungen durch, um Leckagen zu vermeiden.
7. Lagerung:
- Trocken und geschützt lagern: Bewahren Sie die Tankanlage an einem trockenen, frostfreien und vor direkter Sonneneinstrahlung geschützten Ort auf.
- Sicherer Standort: Lagern Sie die Tankanlage fern von Zündquellen und in einem gut belüfteten Bereich.
8. Notfallmaßnahmen:
- Leckagen: Bei einer Leckage Dieselreste sofort mit geeigneten Materialien aufsaugen und gemäß den örtlichen Vorschriften entsorgen.
- Feuer: Verwenden Sie im Brandfall geeignete Löschmittel wie CO₂, Schaum oder Trockenlöschmittel. Wasser ist nicht geeignet.
9. Entsorgung:
- Vorschriftsgemäße Entsorgung: Alte oder beschädigte Tankanlagen sowie Dieselrückstände müssen gemäß den örtlichen Vorschriften entsorgt werden. Informieren Sie sich über die regionalen Bestimmungen für Gefahrgutentsorgung.
Wichtige Hinweise:
- Lesen Sie die Bedienungsanleitung des Herstellers sorgfältig durch, bevor Sie die Tankanlage verwenden.
- Beachten Sie alle Sicherheitsvorschriften des Produktsicherheitsgesetzes und der Gefahrgutverordnung.
Login